All researchers working with cell transfection methods, whether in academia or in industry, know about the pains involved in optimising cell transfection. Sometimes some cells just seem to be more resistant to transfection than others, often for frustratingly vague reasons.

5 point list covering the major factors impacting transfection efficiency

. Use these points as a guide to help you start to optimise your experiments and get more transfected cells.

Is poor transfection efficiency wasting time in your high throughput processes? We can help.

When considering the transfection process as a whole, transfection efficiency and cell viability are intrinsically linked - there's little point in having high transfection efficiency no cells survive.

Factors impacting viability are manifold; if you're seeing low viability of cells prior to transfection, check the following:

: that the media, serum and supplementation requirements are the right ones for your cell line. Each cell line has its own unique requirements.

. Biological contamination of cell lines by bacteria, viruses, mould, yeast, and mycoplasma can occur and impact negatively on the health of your cell. With bacteria, a sudden decrease in pH is often seen; with yeast and mould the pH rises in the later stages of infection. Other warning signs include a turbid cell culture or pronounced cell death. Biological contamination can be prevented by good aseptic technique.

Cross-contamination by other mammalian cell cultures is a widespread and under-diagnosed issue - a study in 1976 tested 246 cell lines and found that a stunning 30% of these were incorrectly labelled. If you're uncertain, look at isotyping, DNA fingerprinting and karyotyping of cells to diagnose the problem.

Cells can also be contaminated by chemical factors (detergents, endotoxins, foreign matter in media).

If you are planning on using antibiotics to treat bacterial contamination, first check that these substances are not toxic at therapeutic doses to your particular cell line.

: Potential toxicity to the cell by your transfectant should be considered as it impacts profoundly on cell viability. If you're trying to express a potentially toxic protein, your system should be

If you’re having issues with cell death in expressing a toxic protein, consider

can routinely help determine, to isolate only the best of your transfected cells.

Choice of cell type will ultimately depend on the function of the experiment. For recombinant protein production the choice of cell line may be all but unimportant; for gene expression characterisation, it could be critical. When choosing, bear these points in mind.

to work with, but their transformation into immortalised cells could represent genetic changes which make them unrepresentative of normal populations, which restricts their use for certain topics.

In our work on improving gene transfection efficiencies for high throughput experiments, we often speak with representatives in industry and academia about their problems with transfection; from this, we know that types generally regarded as

Choice of transfection method is also crucial to the efficiency of the process. Transfection methods can be

There are dozens of choices of each type of product available on the market currently. The two most popular are viral

transfectants are also popular. Traditionally, there was somewhat of a trade-off between transfection efficiency and cell death - particularly with methods such as electroporation - and to a certain extent, it still exists.

Choosing a transfection method isn't exactly straightforward, as the ideal choice depends on what

you want (i.e. stable vs. transient transfection) or on what you're working with. Your target

- the nucleus or the cytoplasm - can influence your choice, as can a need for

requirements of the resulting cells. There are also exceptions to rules; in most cases, serum enhances transfection efficiency; unless you're working with lipofectamine, in which case it interferes with the process.

With all these factors it's no wonder choosing a transfection process is so difficult, and quite often researchers will simply go with the lab default rather than determining what is really optimal for their needs.

How to choose transfection methods is something we'll touch again on later in the series, but is something which needs to be carefully considered before undertaking transfection of cells.

Cell confluency and replication stage are factors intrinsically linked to each other that affect the efficiency of your transfection protocols.

This is because cells that are actively dividing take up DNA more readily than stationary phase cells. Controlling cell confluency is how cells can be kept in an actively dividing state. If cells are allowed to become fully confluent, they begin to exhibit

and cease actively dividing - this limits their ability to uptake nucleic acids and negatively impacts transfection efficiency.

before transfection varies depending on cell type and should always be determined

The nature of what you are inserting into the cell effects the transfection efficiency in several ways. The size and charges of your transfectant in combination with your method of choice can impact the efficiency of transfection. For example, lipid-based transfectants readily transect negatively charged molecules, but uncharged molecules are a challenge.

can use impedance spectroscopy for label-free multiparametric analysis and sorting of cells - and the monitoring of membrane conductivity allows for unparalleled separation of your ideal transfected cell pool. We're currently looking for research partners working with mammalian or plant cells, so if this interests you get in touch with us for a chat.

Have you worked with cells which you found particularly difficult to transfect?

Read the complete available background

All Posts

Inish Cell Analyser

Cell Counting & Viability

Transfection Efficiencies

Microfluidic pumps

Microfluidic chips

Droplet Generation

Organ-on-Chip

Thrombosis

Platelet aggregation

Inish Solutions

Microfluidic Solutions

VenaFlux Solutions

COVID-19

Cell adhesion & migration

Inflammation

Label Free Analysis

Gene Transfection

#CellixTech

We are Cellix

Cellix Out and About

µTas

Cyto Conf 2018

Inish Cell Sorter

Cell Sorting

Stem cells

Search

Low Transfection Efficiency? 5 Points You May Not Have Considered

Vivienne Williams

Jun 28, 2018

5 min read

Updated:

Aug 28, 2020

All researchers working with cell transfection methods, whether in academia or in industry, know about the pains involved in optimising cell transfection. Sometimes some cells just seem to be more resistant to transfection than others, often for frustratingly vague reasons.

So we've put together a

5 point list covering the major factors impacting transfection efficiency

. Use these points as a guide to help you start to optimise your experiments and get more transfected cells.

Is poor transfection efficiency wasting time in your high throughput processes? We can help.

Get in touch.

The 5 major factors that affect transfection efficiency are

1. Cell viability

2. Cell type

3. Transfection Methods used

4. Confluency and replication state

5. Nature of insert or expressed protein

1. Cell Viability

When considering the transfection process as a whole, transfection efficiency and cell viability are intrinsically linked - there's little point in having high transfection efficiency no cells survive.

Prior to transfection, cells should be

>90% viable and

been given time to recover from passaging.

Factors impacting viability are manifold; if you're seeing low viability of cells prior to transfection, check the following:

Nutrition

: that the media, serum and supplementation requirements are the right ones for your cell line. Each cell line has its own unique requirements.

Contamination:

Contamination can be

biological or chemical

. Biological contamination of cell lines by bacteria, viruses, mould, yeast, and mycoplasma can occur and impact negatively on the health of your cell. With bacteria, a sudden decrease in pH is often seen; with yeast and mould the pH rises in the later stages of infection. Other warning signs include a turbid cell culture or pronounced cell death. Biological contamination can be prevented by good aseptic technique.

Cross-contamination by other mammalian cell cultures is a widespread and under-diagnosed issue - a study in 1976 tested 246 cell lines and found that a stunning 30% of these were incorrectly labelled. If you're uncertain, look at isotyping, DNA fingerprinting and karyotyping of cells to diagnose the problem.

Cells can also be contaminated by chemical factors (detergents, endotoxins, foreign matter in media).

If you are planning on using antibiotics to treat bacterial contamination, first check that these substances are not toxic at therapeutic doses to your particular cell line.

Toxicity

: Potential toxicity to the cell by your transfectant should be considered as it impacts profoundly on cell viability. If you're trying to express a potentially toxic protein, your system should be

inducible and non-leaky.

If you’re having issues with cell death in expressing a toxic protein, consider

switching

to a different

promoter-inducer system.

The viability of cells is something our

Inish Analyser technology

can routinely help determine, to isolate only the best of your transfected cells.

2. Cell type

Choice of cell type will ultimately depend on the function of the experiment. For recombinant protein production the choice of cell line may be all but unimportant; for gene expression characterisation, it could be critical. When choosing, bear these points in mind.

Established

cell lines

are generally regarded as

easier

to work with, but their transformation into immortalised cells could represent genetic changes which make them unrepresentative of normal populations, which restricts their use for certain topics.

In our work on improving gene transfection efficiencies for high throughput experiments, we often speak with representatives in industry and academia about their problems with transfection; from this, we know that types generally regarded as

'difficult'

to transfect include

primary

cells,

stem

cells, and cells in

suspension

.

3. Transfection Methods Used

Choice of transfection method is also crucial to the efficiency of the process. Transfection methods can be

physical

or

chemical

, and nucleic acid uptake can also be induced by

viral

transduction of cells.

There are dozens of choices of each type of product available on the market currently. The two most popular are viral

transduction

and

electroporation

, but

lipid-based

transfectants are also popular. Traditionally, there was somewhat of a trade-off between transfection efficiency and cell death - particularly with methods such as electroporation - and to a certain extent, it still exists.

Choosing a transfection method isn't exactly straightforward, as the ideal choice depends on what

outcome

you want (i.e. stable vs. transient transfection) or on what you're working with. Your target

location

- the nucleus or the cytoplasm - can influence your choice, as can a need for

co-transfection

or

purification

requirements of the resulting cells. There are also exceptions to rules; in most cases, serum enhances transfection efficiency; unless you're working with lipofectamine, in which case it interferes with the process.

With all these factors it's no wonder choosing a transfection process is so difficult, and quite often researchers will simply go with the lab default rather than determining what is really optimal for their needs.

How to choose transfection methods is something we'll touch again on later in the series, but is something which needs to be carefully considered before undertaking transfection of cells.

4. Confluency and replication state

Cell confluency and replication stage are factors intrinsically linked to each other that affect the efficiency of your transfection protocols.

This is because cells that are actively dividing take up DNA more readily than stationary phase cells. Controlling cell confluency is how cells can be kept in an actively dividing state. If cells are allowed to become fully confluent, they begin to exhibit

contact inhibition

and cease actively dividing - this limits their ability to uptake nucleic acids and negatively impacts transfection efficiency.

Generally, it is recommended that

passaging

of cells should take place once or twice a week. The

optimal level of confluency

before transfection varies depending on cell type and should always be determined

ab initio

if data cannot be found; very generally, it lies around 70-80%.

5. Nature of Insert

The nature of what you are inserting into the cell effects the transfection efficiency in several ways. The size and charges of your transfectant in combination with your method of choice can impact the efficiency of transfection. For example, lipid-based transfectants readily transect negatively charged molecules, but uncharged molecules are a challenge.

Trying to improve your transfection efficiency?

So are we

.

Our

Inish Analyser

can use impedance spectroscopy for label-free multiparametric analysis and sorting of cells - and the monitoring of membrane conductivity allows for unparalleled separation of your ideal transfected cell pool. We're currently looking for research partners working with mammalian or plant cells, so if this interests you get in touch with us for a chat.

Have you worked with cells which you found particularly difficult to transfect?

Know of any other factors influencing transfection efficiency?

We welcome your comments below, or you can

get in touch.

#TransfectionEfficiency

#CellViability

#EukaryoticCellTransfection

#CellLines

#ImmortalisedCells

#PrimaryCells

#StemCells

#LipidTransfection

#ChemicalTransfection

#CellixTech

#InishAnalyser

Gene Transfection

Label Free Analysis

Transfection Efficiencies

Recent Posts

See All

Getting started with Cellix's Vena8 Glass Coverslip Biochips

Our annual Christmas Sale is back - Check it out before it’s over!

Inish Analyser Data Transfer Protocol

COMPLETE REFERENCE

For illustrations, downloads and the latest updates, visit the original published page.

View original Cellix reference
LET’S MOVE SCIENCE FORWARD

Your next discovery starts here.

Tell us what you’re exploring. We’ll help you find your flow.

Talk to our team

What are you exploring?

Try “droplets”, “Inish” or “cell culture”.

Find your fit.