Big ideas start at the smallest scale.
Technical supporteShop Global distributors
EXPLORE

4U Pump: Simple steps to connect 4U pump to the sample reservoir and flow sensor

Published Cellix background, brought into a clearer, responsive reading experience.

4U Pump: Simple steps to connect 4U pump to the sample reservoir and flow sensor

is a precision pressure pump for a variety of microfluidic applications, where accurate and stable flow rate delivery is required. You can control all the features of the pump with the

for Cellix's microfluidic pumps enable active feedback and PID control. Ideal for microfluidic applications, where accurate and stable flow rate delivery is required resulting in superior performance. Flow sensors are compatible with the

: flow sensors are suitable for use with ExiGo syringe pumps, UniGo and 4U pressure pumps so you can mix-and-match syringe and pressure pumps giving greater flexibility for your microfluidic set-up.

: 1µL, 1.5µL, 5µL & 25µL dead volume for 1.5µL, 7µL, 80µL & 1mL sensors, respectively.

Push the tubing into the port of the sample reservoir and push the other end of the tubing into port to 4U Pump.

Insert the tubing into the port for tubing located on the top of the sample reservoir and secure it with screws.

So now you’ve set up your 4U Pump and the flow sensor, and you know how each piece works. But, if you still have questions or want to learn more, check out our website, at

Droplet generation of water-in-oil droplets using Cellix's 4U Pump: a step-by-step process

4U 4-channel Microfluidic Pump: Accurate and Pulse-Free Flow for Microfluidic Applications

Read the complete available background

All Posts

Inish Cell Analyser

Cell Counting & Viability

Transfection Efficiencies

Microfluidic pumps

Microfluidic chips

Droplet Generation

Organ-on-Chip

Thrombosis

Platelet aggregation

Inish Solutions

Microfluidic Solutions

VenaFlux Solutions

COVID-19

Cell adhesion & migration

Inflammation

Label Free Analysis

Gene Transfection

#CellixTech

We are Cellix

Cellix Out and About

µTas

Cyto Conf 2018

Inish Cell Sorter

Cell Sorting

Stem cells

Search

4U Pump: Simple steps to connect 4U pump to the sample reservoir and flow sensor

Cellix Technical Team

Apr 18, 2024

2 min read

Introduction

4U 4-channel microfluidic pump

is a precision pressure pump for a variety of microfluidic applications, where accurate and stable flow rate delivery is required. You can control all the features of the pump with the

SmartFlo

software running on PC.

Features and Benefits

FAST RESPONSE

and fast settling time.

PULSE-FREE

down to µL/min with flow sensor.​

PROGRAMMABLE

flow profiles with any combination of constant, ramp, sine and step.

EASY INTEGRATION

with your own software - LabVIEW, C++, Python, etc.

FLOW RATES

: 1µL/min - 1mL/min.

INPUT PRESSURE:

up to 10 bar or 145 PSI - external compressor or vacuum pump required.

CLOSED-LOOP FEEDBACK

:

Flow sensors provide active feedback and precise flow control.

EASY TO USE:

simple software control via SmartFlo software or LabVIEW.

Flow Sensor

Flow sensors

for Cellix's microfluidic pumps enable active feedback and PID control. Ideal for microfluidic applications, where accurate and stable flow rate delivery is required resulting in superior performance. Flow sensors are compatible with the

ExiGo, UniGo and 4U microfluidic pumps.

Features and Benefits

CLOSED-LOOP FEEDBACK:

Flow sensors provide active feedback and precise flow control.

MODULAR

: flow sensors are suitable for use with ExiGo syringe pumps, UniGo and 4U pressure pumps so you can mix-and-match syringe and pressure pumps giving greater flexibility for your microfluidic set-up.

FLOW RANGES

: 1.5µL, 7µL, 80µL and 1mL sensors available.

LOW DEAD VOLUME

: 1µL, 1.5µL, 5µL & 25µL dead volume for 1.5µL, 7µL, 80µL & 1mL sensors, respectively.

4U Pump: Connecting sample reservoir and flow sensor

Connect 4U Pump to a 15mL Sample Reservoir and Flow Sensor.

Twist and push the tube and connect it to the Sample Reservoir.

Push the tubing into the port of the sample reservoir and push the other end of the tubing into port to 4U Pump.

Insert the tubing into the port for tubing located on the top of the sample reservoir and secure it with screws.

Screw other end of the tubing into the input port of the Flow Sensor.

Screw tubing to chip into output port of the flow sensor.

Connect cable to 4U Pump.

So now you’ve set up your 4U Pump and the flow sensor, and you know how each piece works. But, if you still have questions or want to learn more, check out our website, at

wearecellix.com

, or contact us

here.

Tags:

microfluidic pumps

microfluidic chips

Microfluidic Solutions

VenaFlux Solutions

Microfluidic chips

Recent Posts

See All

Droplet generation of water-in-oil droplets using Cellix's 4U Pump: a step-by-step process

4U 4-channel Microfluidic Pump: Accurate and Pulse-Free Flow for Microfluidic Applications

All you need to know about your 4U Pump

COMPLETE REFERENCE

For illustrations, downloads and the latest updates, visit the original published page.

View original Cellix reference
LET’S MOVE SCIENCE FORWARD

Your next discovery starts here.

Tell us what you’re exploring. We’ll help you find your flow.

Talk to our team

What are you exploring?

Try “droplets”, “Inish” or “cell culture”.

Find your fit.