Cell counting & viability

Published Cellix background, brought into a clearer, responsive reading experience.

Cell counts and cell viability are key metrics of every cell-based assay.  Analysis of these key metrics are performed daily in thousands of labs around the world for R&D applications and Quality Control in biomanufacturing of cell-based products for gene therapy, stem cell research and cancer cell research.  These metrics are important because they provide information about the overall health of the cells while experiments are being carried out on the cells and ensuring quality control during cell manufacturing processes.

takes the pain away and gives you an automatic cell count and viability measurement in minutes - and that includes sample preparation! Unlike laborious manual cell counting with haemocytometers; image-based analysis or flow cytometry, the

Cell Counting & Viability of Primary T-cells (isolated from whole blood)

Cell Counting & Viability of Stem cells (Human Bone-Marrow derived Mesenchymal Stem Cells)

Cell Counting & Viability of Primary T-cells (isolated from whole blood)

On the scatterplot, there may be up to 3 visible populations depending on your restuls:

Debris population is represented by the population of dots on the left-hand side of the scatterplot along the Y-axis.

"Gating” the populations means selecting the population(s) of interest for analysis. For the Cell Counting & Viability Assay, this means determining where the horizontal and vertical lines are positioned:

Vertical Line: Left-hand side of this line is where the Debris population is positioned.

The horizontal line is positioned by default at the centre-point, ideally separating the Live cell population from the Dead cell population. However, it may require minor adjustment and you can move the line by placing your finger on the line and sliding it up or down the scatterplot as required. Similarly for the vertical line, you can place your finger on it and slide it left or right. The accompanying table with all the results will be updated accordingly.

; to the most commonly used methods for cell counting and viability which all use

Traditionally, cell counting and viability analysis is performed by staining the cells. DAPI (4', 6-diamido-2-phenylindole) and Hoechst are commonly used stains or dyes for

There are now a range of cell viability stains available, including Trypan Blue for dead cells (

Manual step of cell staining.  Depending on the cell staining kit or dyes used, it can take up to one hour to complete the sample preparation of staining the cells.

Haemocytometers are counting chambers and they have been used by cell biologists for >100 years.  Despite the recent introduction of semi-automated methods such as those described here (i.e. image analysis and flow cytometry); haemocytometers are still a mainstay of many cell biology laboratories worldwide.  But recurring challenges with haemocytometer-based cell counting is resulting in the gradual replacement of these methods.

Manual counting means that this is inevitable at multiple stages of the process including mixing, handling and dilution.

Due to the manual nature of the process, it is not suited for large scale analyses or processes which require a high throughput cell analysis.

As multiple counts are required to ensure consistency, it often leads to poor reproducibility especially across user-to-user testing of a cell sample.

As this is a DIY method, each researcher will use different buffers, different pipettes and these differences can result in further unwanted errors.

As computer processing capabilities have increased in recent years, so too has the rise of computer-based image cytometry.  With more robust machine learning and image analysis algorithms, computers can now quantitatively analyse cellular images detecting features that may not be detected by the human eye.  Instruments relying on this method include a digital camera (to take the image of the cells) and a computer program to analyse the image. The camera must take a good quality image with "

- good quality images are easier for the computer algorithm to analyse.  Thus, these devices often

nsures the cells are in focus before images are taken.  To ensure correct presentation of the cell sample in front of the camera, these instruments typically use specialist slides or cartridges which are specific to the instrument.

While image-based analysis has gained traction in recent years, there are a number of disadvantages to this method:

Adjustments in staining are often required to obtain a better resolution of cells from the background image.  High Trypan blue concentration can lead to background noise and interfere with the ability of the instrument to correctly analyse and distinguish cells.

The user must stain the cells before loading the cell sample in the slide or cartridge.

As each instrument has a chamber, slide or cartridge which is specific to that instrument, end-users are tied to the high cost of consumables for every assay.

Advances in image-based analysis include image-based cytometers (high-resolution imaging in microscopy of single cells in flowing environments).  While popular in recent years, these instruments face computational challenges in handling large volumes of image data that need to be processed which limits their use for clinical applications.

Flow cytometry method involves flowing cells, one at a time, past a light source (e.g. laser) and a detector.  As the cell passes the light source, the scattered light is collected by the detector and analysed.  Cells are labeled with fluorescent stains which result in absorption and emission of light at different wavelengths.  Depending on the wavelength of the emitted light, different characteristics of the labelled cell can be measured.

Most flow cytometers are relatively complex instruments which are overkill for applications such as simple cell counting and viability analysis.  While there are more bench-top flow cytomters on the market now, many are still confined to flow cytometry core facilities operated by technicians.

As flow cytometers are capable of multi-parametric analysis (including cellular component analysis such as organelles, nuclei, DNA, RNA, chromosomes, cytokines, hormones and protein content); these instruments command a much higher price compared to simplified image-based analysis instruments.

Cell counts are particularly important in cases where cells are being cultured for another purpose e.g. further experimentation or where the cells themselves are the product, such as cell therapy.  Depending on the experiments or cell manufacturing processes to which the cells are exposed, cell viability may be affected.  This means that cell viability is often checked at various points throughout an experiment or process.

Dispensing of cells from cell sorters results in a large drop in pressure (often referred to as "

Experiments which can result in increased temperatures (e.g. certain biomaterials required for 3D cell printing) need to be planned carefully to avoid exposing cells to high temperatures.

Experiments which deprive the cells of access to nutrients for prolonged periods of time can adversely affect cellular health.

A critical test which all substances, including drugs, must pass before being approved.  As a result, toxicity screening ("tox screens") are a huge area of study whereby cells are purposefully exposed to different concentrations of a substance to determine their level by which cell viability is affected.  Important for new drug therapies and also to determine safe usage of every-day chemicals in the home.

Forces induced by the walls of flow cells or the walls of a needle - these forces tend to have less of an effect compared with pressure.

Read the complete available background

Cell Counting & Viability

Cell counts and cell viability are key metrics of every cell-based assay.  Analysis of these key metrics are performed daily in thousands of labs around the world for R&D applications and Quality Control in biomanufacturing of cell-based products for gene therapy, stem cell research and cancer cell research.  These metrics are important because they provide information about the overall health of the cells while experiments are being carried out on the cells and ensuring quality control during cell manufacturing processes.

INISH SOLUTIONS

COMPARE WITH CURRENT METHODS

WHY MEASURE CELL COUNTS & VIABILITY?

Inish Solutions

Inish Solutions for Cell Counting & Viability

Cellix's

Inish Analyser

takes the pain away and gives you an automatic cell count and viability measurement in minutes - and that includes sample preparation! Unlike laborious manual cell counting with haemocytometers; image-based analysis or flow cytometry, the

Inish Analyser requires no cell staining

.  This reduces the steps in your workflow, giving you

true automated cell counting.

Results

Results are displayed in the form of a scatterplot and in a table.

Cell Counting & Viability of Primary T-cells (isolated from whole blood)

Cell Counting & Viability of Stem cells (Human Bone-Marrow derived Mesenchymal Stem Cells)

Cell Counting & Viability of Jurkat T-cells

Cell Counting & Viability of Primary T-cells (isolated from whole blood)

On the scatterplot, there may be up to 3 visible populations depending on your restuls:

Live

cell population is represented by the

green

dots.

Dead

cell population is represented by the

red

dots.

Debris population is represented by the population of dots on the left-hand side of the scatterplot along the Y-axis.

Gating Populations

"Gating” the populations means selecting the population(s) of interest for analysis. For the Cell Counting & Viability Assay, this means determining where the horizontal and vertical lines are positioned:

Horizontal Line: Above the line is where the

Live

cell population is positioned and below the line is where the

Dead

cell population is positioned.

Vertical Line: Left-hand side of this line is where the Debris population is positioned.

The horizontal line is positioned by default at the centre-point, ideally separating the Live cell population from the Dead cell population. However, it may require minor adjustment and you can move the line by placing your finger on the line and sliding it up or down the scatterplot as required. Similarly for the vertical line, you can place your finger on it and slide it left or right. The accompanying table with all the results will be updated accordingly.

Compare with Current Methods

Cell Staining

Haemocytometer

Imag-based Analysis

Flow Cytometery

Compare with Current Methods

The table below compares Cellix's Inish Analyser which uses

impedance spectroscopy

; to the most commonly used methods for cell counting and viability which all use

cell staining

:

Haemocytometer (Hemocytometer)

Image-based Analysis

Flow Cytometry

Compare Inish Analyser with current methods

Pros & Cons of Inish Analyser vs. current methods

Compare Inish Analyser with current methods

Traditional Cell Counting & Viability Analysis:  Cell Staining

Traditionally, cell counting and viability analysis is performed by staining the cells. DAPI (4', 6-diamido-2-phenylindole) and Hoechst are commonly used stains or dyes for

cell counting

.  They stain the nucleus of both live and dead cells and appear

blue

in colour.

A common example of

cell viability

stains include:

Live

cells stained with a

green stain

(Calcein AM) and

Dead

cells with a

red stain

(Propidium Iodide)

There are now a range of cell viability stains available, including Trypan Blue for dead cells (

blue stain

) and Erythrosine B for dead cells (

pink stain

).

Problems with Cell staining:

Time consuming:

Manual step of cell staining.  Depending on the cell staining kit or dyes used, it can take up to one hour to complete the sample preparation of staining the cells.

Stains affect cell functionality:

The addition of a stain itself can affect cell functionality.

Haemocytometers / Hemocytometers

Haemocytometers are counting chambers and they have been used by cell biologists for >100 years.  Despite the recent introduction of semi-automated methods such as those described here (i.e. image analysis and flow cytometry); haemocytometers are still a mainstay of many cell biology laboratories worldwide.  But recurring challenges with haemocytometer-based cell counting is resulting in the gradual replacement of these methods.

Challenges of Haemocytometer Cell Counting:

Human Error:

Manual counting means that this is inevitable at multiple stages of the process including mixing, handling and dilution.

Time consuming:

Due to the manual nature of the process, it is not suited for large scale analyses or processes which require a high throughput cell analysis.

Poor reproducibility:

As multiple counts are required to ensure consistency, it often leads to poor reproducibility especially across user-to-user testing of a cell sample.

Material variation:

As this is a DIY method, each researcher will use different buffers, different pipettes and these differences can result in further unwanted errors.

^Back to Table

Image-based Analysis

As computer processing capabilities have increased in recent years, so too has the rise of computer-based image cytometry.  With more robust machine learning and image analysis algorithms, computers can now quantitatively analyse cellular images detecting features that may not be detected by the human eye.  Instruments relying on this method include a digital camera (to take the image of the cells) and a computer program to analyse the image. The camera must take a good quality image with "

cells-in-focus

"

- good quality images are easier for the computer algorithm to analyse.  Thus, these devices often

have a manual focus or auto-focus setting - this e

nsures the cells are in focus before images are taken.  To ensure correct presentation of the cell sample in front of the camera, these instruments typically use specialist slides or cartridges which are specific to the instrument.

While image-based analysis has gained traction in recent years, there are a number of disadvantages to this method:

Challenges of Image-based Analysis:

Manual adjustments are required:

Adjustments in staining are often required to obtain a better resolution of cells from the background image.  High Trypan blue concentration can lead to background noise and interfere with the ability of the instrument to correctly analyse and distinguish cells.

Semi-automatic:

The user must stain the cells before loading the cell sample in the slide or cartridge.

High cost per assay:

As each instrument has a chamber, slide or cartridge which is specific to that instrument, end-users are tied to the high cost of consumables for every assay.

Large volumes of imaging data:

Advances in image-based analysis include image-based cytometers (high-resolution imaging in microscopy of single cells in flowing environments).  While popular in recent years, these instruments face computational challenges in handling large volumes of image data that need to be processed which limits their use for clinical applications.

^Back to Table

Flow Cytometry

Flow cytometry method involves flowing cells, one at a time, past a light source (e.g. laser) and a detector.  As the cell passes the light source, the scattered light is collected by the detector and analysed.  Cells are labeled with fluorescent stains which result in absorption and emission of light at different wavelengths.  Depending on the wavelength of the emitted light, different characteristics of the labelled cell can be measured.

Challenges of Flow Cytometry:

Complex instrumentation:

Most flow cytometers are relatively complex instruments which are overkill for applications such as simple cell counting and viability analysis.  While there are more bench-top flow cytomters on the market now, many are still confined to flow cytometry core facilities operated by technicians.

High instrument cost:

As flow cytometers are capable of multi-parametric analysis (including cellular component analysis such as organelles, nuclei, DNA, RNA, chromosomes, cytokines, hormones and protein content); these instruments command a much higher price compared to simplified image-based analysis instruments.

^Back to Table

Why Measure Cell Counts & Viability?

Why Measure Cell Counts & Viability?

Cell counts are particularly important in cases where cells are being cultured for another purpose e.g. further experimentation or where the cells themselves are the product, such as cell therapy.  Depending on the experiments or cell manufacturing processes to which the cells are exposed, cell viability may be affected.  This means that cell viability is often checked at various points throughout an experiment or process.

Factors which affect cell viability include:

Pressure:

Dispensing of cells from cell sorters results in a large drop in pressure (often referred to as "

explosive decompression

") which can affect cell viability.

Temperature:

Experiments which can result in increased temperatures (e.g. certain biomaterials required for 3D cell printing) need to be planned carefully to avoid exposing cells to high temperatures.

Availability of sufficient nutrients:

Experiments which deprive the cells of access to nutrients for prolonged periods of time can adversely affect cellular health.

Exposure to toxic substances:

A critical test which all substances, including drugs, must pass before being approved.  As a result, toxicity screening ("tox screens") are a huge area of study whereby cells are purposefully exposed to different concentrations of a substance to determine their level by which cell viability is affected.  Important for new drug therapies and also to determine safe usage of every-day chemicals in the home.

Shear forces:

Forces induced by the walls of flow cells or the walls of a needle - these forces tend to have less of an effect compared with pressure.

RELATED BLOGS

RECOMMENDED PRODUCTS

REQUEST MORE INFORMATION

RELATED BLOGS

Our annual Christmas Sale is back - Check it out before it’s over!

Cellix Technical Team

Nov 28, 2022

2 min read

Inish Analyser Data Transfer Protocol

Cellix Technical Team

Nov 7, 2022

3 min read

How to analyse data using the Inish Analyser?

Cellix Technical Team

Oct 17, 2022

3 min read

Related Blogs

Recommended Products

RECOMMENDED PRODUCTS

Inish Analyser

Inish Calibration Kit

Sample & Waste Tubes

Inish Analyser Buffer

Inish Cleaning Fluid

Inish Solutions query

Get a Quote or more information

COMPLETE REFERENCE

For illustrations, downloads and the latest updates, visit the original published page.